電流鉤鉗-Fluke 80i-2010S
An open-jaw, clamp-on current probe with a current range of 2000 A, and an accuracy of 0.8%, that is also safety rated for CAT III 1000 V, CAT IV 600 V environments.
建議售價: 請來電洽詢報價
- 特色
- 規格
- 下載
Available in packs of one, or as a three pack the Fluke 80i-2010s allows you to measure up to 2,000A AC and/or DC on large conductors with 0.8% accuracy. The 80i-2010S provides a convenient way to measure current without having to disconnect the load.
Key features
Conveniently measure current without having to disconnect the load
2,000A AC and DC current clamp
Maximum conductor size – 52mm (2.05in)
Maximum opening – 81.5mm (3.2in)
Specifications: Fluke 80i-2010s AC/DC Current Clamps
General Specifications | |||
Modules | 80i-2010s | ||
Dimensions | 110 mm x 270 mm x 46mm | ||
Weight | 0.710 kg (1.6 lbs), including battery | ||
Output Cable | 1.5 m (60 in) Shielded Coaxial cable with BNC plug | ||
Maximum Conductor Size | 52.0 mm (2.05 in) | ||
Maximum Jaw Opening | 81.5 mm | ||
Output to Zero | Auto adjustment with Zero button | ||
Temperature Operating | -10 °C to 50 °C (14 °F to 122 °F) | ||
Storage (battery removed) | -30 °C to +60 °C (-22 °F to +140 °F) | ||
Operating Humidity | ≤ 90 % RH (at 10 °C to 30 °C) ≤ 75 % RH (at 30 °C to 40 °C) ≤ 45 % RH (at 40 °C to 50 °C) | ||
Operating Altitude | 2,000 m (6560 ft) | ||
Storage Altitude | 12,000 m (40,000 ft) | ||
Demagnetize Clamp | Open and close the Clamp jaws several times with soft click, use of the clamp on uninsulated conductors is limited to 1000 Vac rms or DC and frequencies 1 kHz or less. | ||
Safety | IEC 61010-1, Pollution Degree 2, IEC 61010-2-032: CAT III 1000 V /CAT IV 600 V | ||
Ingress Protection | IEC 60529, IP40 | ||
Power Supply Type | 2 x AA alkaline battery, IEC LR6 | ||
Battery Life | 150 hours (typically) | ||
Low battery indicator | Yes |
Electrical Specifications | |||
Current Range | 2000 A ac rms, ± 2000 A dc | ||
Output Sensitivity | 01 mV/A | ||
Accuracy | ± 0.8 % of reading ± 0.2 % of range | ||
Bandwidth for Accuracy Specification | DC to 400 Hz | ||
Load impedance | >1 MΩ and<10 pF | ||
Frequency Response (small signal) | DC to 20 kHz (-3 dB) | ||
Temperature Coefficient | 0.1 x specified accuracy for each degree C above 28 °C or below 18 °C | ||
Working Voltage | 1000 V AC RMS or DC |