Amprobe 加固型萬用表-HD110C
HEAVY DUTY DMM, IP67, 1500V DC
建議售價: 請來電洽詢報價
- 特色
- 規格
- 下載
The Amprobe HD110C Heavy Duty Multimeter is designed for professional use in harsh environments. The meter is unusually rugged and reliable in everyday heavy use applications. Its made using waterproof construction to prevent dirt, grime and moisture from entering the case and causing inaccurate readings or damaging shorts.
Built of tough, fire-retardant thermoplastic resistant to grease and chemical spills, with all sensitive components shock-mounted for a drop resistant to at least eight feet. The HD110C has an extended voltage measurement capability of 1500 V DC and 1000 V AC, unmatched by any other line of digital multimeters. The extended voltage ranges can withstand transients up to 12 kV.
Highest voltage capability, measuring to 1500 V DC and 1000 V AC
CAT IV 1000 V rated
Special sealing for environment and water resistance: IP67 rated
Constructed with drop-resistant housing and PCB mounting
Magne-Grip™ holster, frees both hands for work
Includes high voltage test leads with threaded alligator clips
Display 3-1/2 digit LCD, 1999 counts, with annunciators
Automatic polarity indication
Low battery indication
Standard 9 V battery, NEDA 1604, JIS 006P,IEC 6F2
Flame retardant, high-impact thermoplastic case
Resistance ranges 200 Ω, 2 kΩ, 20 kΩ, 200 kΩ, 2 MΩ, 20 MΩ
FEATURE | HD110C | HD160C |
DC Voltage | 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1500 V | 1000.0 mV, 10.000 V, 100.00 V, 1500.0 V |
AC Voltage | 200.0 mV, 2.000 V, 20.00 V, 200.0 V, 1000 V | 1000.0 mV, 10.000 V, 100.00 V, 1000.0 V |
Current | AC/DC 200.0 µA, 2.000 mA, 20.00 mA, 200.0 mA, 2 A | 100.00 µA, 1000.0 µA, 10.000 mA, 100.00 mA, 400.0 mA, 2.000 A |
Resistance | 200.0 O, 2.000 kO, 20.00 kO, 200.0 kO, 2.000 MO, 20.00 MO | 1000.0 O, 10.00 kO, 100.00 kO, 1000.0 kO, 10.000 MO, 40.00 MO |
Diode | • | – |
Continuity | • | |
Frequency | – | 100.00 Hz, 1000.0 Hz, 10.000 kHz, 100.00 kHz, 1000.0 kHz, 10.000 M Hz |
Capacitance | – | 40.00 nF, 400.0 nF, 4.000 µF, 40.00 µF, 400.0 µF |
Temperature | – | -4 °F → 2372 °F (-20 °C → 1300°C) |
True-rms | – | • |
Specifications | |
DC Volts range: | 200 mV, 2 V, 20 V, 200 V, 1500 V |
DC Volts resolution: | 0.1 mV |
DC Volts accuracy: | All ranges ±(0.1 % rdg+2 dgts) |
DC Volts input impedance: | 10 MO |
DC Volts OL protection: | >1500 V DC/1000 V AC rms |
DC Volts transient protection: | >12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV |
AC Volts (45 Hz to 2 kHz) ranges: | 200 mV, 2 V, 20 V, 200 V, 1000 V |
AC Volts (45 Hz to 2 kHz) resolution: | 0.1 mV |
AC Volts (45 Hz to 2 kHz) accuracy: | 200 mV to 200 V (45-500 Hz) ±(0.8 % rdg+4 dgts), |
AC Volts (45 Hz to 2 kHz) accuracy: | 200 mV to 200 V (500 Hz-2 kHz) ±(1.5 % rdg+5 dgts) |
AC Volts (45 Hz to 2 kHz) accuracy: | 1000 V (50-60 Hz) ±(0.8 % rdg+4 dgts) |
AC Volts (45 Hz to 2 kHz) accuracy: | 1000 V (60-500 Hz) ±(1.5 % rdg+5 dgts) |
AC Volts (45 Hz to 2 kHz) input impedance: | 10 MO |
AC Volts (45 Hz to 2 kHz) OL protection: | 1500 V DC/1000 V AC rms |
AC Volts (45 Hz to 2 kHz) transient protection: | 12 kV impulse (1.2 µS/50 µS) based on EN 61010-1:2001 impulse requirement for at CAT IV 1000 V product. This product should not be used in installations where transients exceed 12 kV. |
DC Current range: | 200 µA, 2 mA, 20 mA, 200 mA, 2 A |
DC Current resolution: | 0.1 µA |
DC Current accuracy: | 200 µA to 20 mA ±(0.5 % rdg+2 dgts) |
DC Current accuracy: | 200 mA to 2 A ±(1.0 % rdg+2 dgts) |