Combo Kit-Fluke 179-EDA2
Rugged Kit for Rugged Environments
We know industrial electricians work in tough environments, that's why we have kitted our Fluke 179 True RMS digital multimeter with industrial strength test lead probe kit in a compact lightweight soft case.建議售價: 請來電洽詢報價
- 特色
- 規格
Fluke 179/EDA2 Kit
Electronic's Combo Kit
Includes:
Fluke 179 Multimeter
80BK-A Integrated DMM Temperature Probe
Installed 9V battery
Users’ manual
AC280 SureGrip™ Hook Clips
TL910 Electronic Test Probes
TL224 SureGrip™ Insulated Test Leads
TPAK ToolPak™ Magnetic Meter Hanger
Soft carry case
Specifications | ||
Voltage DC | Accuracy1 | ±(0.09% + 2) |
Max. resolution | 0.1 mV | |
Maximum | 1000 V | |
Voltage AC | Accuracy1 | ±(1.0% + 3) |
Max. resolution | 0.1 mV | |
Maximum | 1000 V | |
Current DC | Accuracy1 | ±(1.0% + 3) |
Max. resolution | 0.01 mA | |
Maximum | 10 A | |
Current AC | Accuracy1 | ±(1.5% + 3) |
Max. resolution | 0.01 mA | |
Maximum | 10 A | |
Resistance | Accuracy1 | ±(0.9% + 1) |
Max. resolution | 0.1 Ω | |
Maximum | 50 MΩ | |
Capacitance | Accuracy1 | ±(1.2% + 2) |
Max. resolution | 1 nF | |
Maximum | 10,000 µF | |
Frequency | Accuracy1 | ±(0.1% + 1) |
Max. resolution | 0.01 Hz | |
Maximum | 100 kHz | |
Temperature | Accuracy1 | ±(1.0% + 10) |
Max. resolution | 0.1°C | |
Range | -40°C / 400°C | |
1. Accuracies are best accuracies for each function | ||
Environmental Specifications | ||
Operating temperature | -10°C to +50°C | |
Storage temperature | -30°C to +60°C | |
Humidity (without condensation) | 0% - 90% (0°C - 35°C) 0% - 70% (35°C -50°C) | |
Safety Specifications | ||
Overvoltage category | EN 61010-1 to 1000 V CAT III EN 61010-1 to 600 V CAT IV | |
Agency approvals | UL, CSA, TÜV listed and VDE Pending | |
Mechanical and General Specifications | ||
Size | 43 x 90 x 185 mm | |
Weight | 420 g | |
Warranty | Lifetime | |
Battery life | Alkaline ~200 hours typical, without backlight |